Chiminey Installation Guide

This document describes how to install a Chiminey platform via Docker, which is an automatic software deployment tool.

Requirements

Docker 1.7+ is needed. Follow the links below to install docker on your machine.

Mac OS X and Windows

Here, we create a virtual machine that runs docker.

  1. Download Docker Toolbox from https://www.docker.com/toolbox.
  2. When the download is complete, open the installation dialog box by double-clicking the downloaded file.
  3. Follow the on-screen prompts to install the Docker toolbox. You may be prompted for password just before the installation begins. You need to enter your password to continue.
  4. When the installation is completed, press Close to exit.
  5. Verify that docker-engine and docker-compose are installed correctly.
  • Open Docker Quickstart Terminal from your application folder. The resulting output looks like the following:
Docker Terminal on Mac OS X or Windows

Figure. Docker Virtual Machine on Mac OS X or Windows

  • Run docker engine:

    $ docker run hello-world
    
    • You will see a message similar to the one below:

      Unable to find image ’hello-world:latest’ locally
      latest: Pulling from library/hello-world
      03f4658f8b78: Pull complete
      a3ed95caeb02: Pull complete
      Digest: sha256:8be990ef2aeb16dbcb92...
      Status: Downloaded newer image for hello-world:latest
      Hello from Docker.
      This message shows that your installation appears to be
          working correctly.
      ...
      
  • Run docker-compose:

    $ docker-compose --version
    
    • The output will be docker-compose version x.x.x, build xxxxxxx

    • For users with an older Mac, you will get Illegal instruction: 4. This error can be fixed by upgrading docker-compose:

      $ pip install --upgrade docker-compose
      

Linux

Docker, specifically docker-engine and docker-compose, needs to be installed directly on your linux-based OS. Refer to the Docker online documentation to install the two packages:

  1. Install docker-engine
  2. Install docker-compose

Installation

  1. For Mac OS X and Windows users, open Docker Quickstart Terminal. For linux-based OS users, login to your machine and open a terminal.

  2. Check if git is installed. Type git on your terminal.

    • If git is installed, the following message will be shown:

      usage: git [--version] [--help] [-C <path>] ..
                 [--exec-path[=<path>]] [--html-path] [...
                 [-p|--paginate|--no-pager] [--no- ...
                 [--git-dir=<path>] [--work-tree=<path>]...
                 <command> [<args>]
                 ...
      
    • If git is not installed, you will see git: command not found. Download and install git from http://git-scm.com/download

  3. Clone the docker-chiminey source code from http://github.com.au:

    $ git clone https://github.com/chiminey/docker-chiminey.git
    
  4. Change your working directory:

    $ cd docker-chiminey
    
  5. Setup a self-signed certificate. You will be prompted to enter country code, state, city, and etc:

    $ sh makecert
    
  6. Deploy the Chiminey platform:

    $ docker-compose up -d
    
  7. Verify Chiminey was deployed successfully.

  • Retrieve the IP address of your machine

    • For Mac and Windows users, type env | grep DOCKER_HOST. The expected output has a format DOCKER_HOST=tcp://IP:port, for example. DOCKER_HOST=tcp://192.168.99.100:2376. Thus, your IP address is 192.168.99.100.
    • For linux users, the command ifconfig prints your our machine’s IP address.
  • Open a browser and visit the Chiminey portal at IP, in our example, http://192.168.99.100. After a while, the Chiminey portal will be shown.

    Chiminey Portal

    Figure. Chiminey Portal

Configuration

Here, we will configure the Chiminey deployment by creating a superuser, initialising the database, and signing up a regular user.

  1. For Mac OS X and Windows users, open Docker Quickstart Terminal. For linux-based OS users, login to your machine and open a terminal.

  2. Change to docker-chiminey directory:

    $ cd docker-chiminey
    
  3. Create a superuser:

    $ ./createsuper
    
  4. Initialise the database:

    $ ./init
    
  5. Create a regular user:

    $ ./createuser
    
  6. Verify the Chiminey platform is configured correctly.

  • Open a browser and visit the Chiminey portal.
  • Login with your regular username and password. After successful login, you will be redirected to a webpage that displays a list of jobs. Since no jobs are run yet, the list is empty.

Smart Connectors Activation

When a Chiminey platform is deployed, each smart connector <smart_connector_desc>, which is the core concept within Chiminey that enables endusers to perform complex computations on distributed computing facilities with minimal effort, needs to be explicitly activated.

  1. For Mac OS X and Windows users, open Docker Quickstart Terminal. For linux-based OS users, login to your machine and open a terminal.

  2. Change to docker-chiminey directory:

    $ cd docker-chiminey
    
  3. List all available smart connectors:

    $ ./listsc
    
    NAME:       DESCRIPTION
    hrmclite:   Hybrid Reverse Monte Carlo without PSD
    randnum:    Randnum generator, with timestamp
    wordcount:  Counting words via Hadoop
    
  4. Activate a smart connector. The syntax to activate a smart connector is ./activatesc smart-connector-name. Thus, activate randnum smart connector as follows:

    $ ./activatesc randnum
    
  5. Verify the smart connector is successfully activated.

  • Open a browser and visit the Chiminey portal.
  • Login with your regular username and password.
  • Click Create Job. randnum will appear under the Smart Connectors list.

See also

https://www.djangoproject.com/
The Django Project
https://docs.djangoproject.com/en/1.4/intro/install/
Django Quick Install Guide

Enduser Manual

An end-user submits a smart connector job, monitors the job, visualises and curates job results. In this documentation, following topics are covered:

Getting Chiminey Account

Chiminey accounts are managed by admin users. Therefore, in order to get access to a specific Chiminey deployment, the end-user should contact the admin of the deployed Chiminey platform.

Login

End-users login via the web interface of the Chiminey platform

  1. Click login on the home page
  2. Enter Chiminey credentials
  3. Click Login
_images/login.png

Logout

  1. click Logout
_images/logout.png

Resource Management

A Chiminey platform supports access to computation and storage resources. A computation resource is where the core functionality of a smart connector is executed while a storage resource is used to retrieve input files and store output files. Prior to submitting a job, end-users need to register at least one computation and one storage resources. In this section, following topics are covered:

Registering Compute Resources

Various computing infrastructure and tools can be registered as compute resources. These resources are broadly categorised under cloud, high performance computing (HPC), analytics, and continuous integration resources.

Cloud Compute Resource
  1. Navigate to the Chiminey portal.
  2. Log in with your credentials.
  3. Click Settings.
  4. Click Compute Resource from the Settings menu.
  5. Click Register Compute Resource
  6. Click the Cloud tab.
  7. Select the resource type from the drop down menu. You may have access to more than one type of cloud service, e.g., NeCTAR and Amazon.
  8. Enter a unique resource name.
  9. Enter credentials such as EC2 access key and EC2 secret key
  10. Click Register. The newly registered cloud-based compute resource will be displayed under Cloud - NeCTAR/CSRack/Amazon EC2.
Registering a cloud-based compute resource

Figure. Registering a cloud-based compute resource

HPC Compute Resource
  1. Navigate to the Chiminey portal.
  2. Log in with your credentials.
  3. Click Settings.
  4. Click Compute Resource from the Settings menu.
  5. Click Register Compute Resource
  6. Click the HPC tab.
  7. Enter a unique resource name.
  8. Enter IP address or hostname of the HPC cluster head node or the standalone server.
  9. Enter credentials, i.e. username and password. Password is not stored in the Chiminey platform. It is temporarily kept in memory to establish a private/public key authentication from the Chiminey platform to the resource.
  10. Click Register. The newly registered resource will be displayed under HPC - Cluster or Standalone Server list.
Registering a HPC compute resource

Figure. Registering a HPC compute resource

Analytics Compute Resource
  1. Navigate to the Chiminey portal.
  2. Log in with your credentials.
  3. Click Settings.
  4. Click Compute Resource from the Settings menu.
  5. Click Register Compute Resource
  6. Click the Analytics tab.
  7. Select Hadoop MapReduce as the resource type from the drop down menu.
  8. Enter a unique resource name.
  9. Enter IP address or hostname of the Hadoop MapReduce resource.
  10. Enter username and password. Password is not stored in the Chiminey platform. It is temporarily kept in memory to establish a private/public key authentication from the Chiminey platform to the resource.
  11. Click Register. The newly registered resource will be displayed under Analytics - Hadoop MapReduce list.
Registering an analytics compute resource (Hadoop MapReduce)

Figure. Registering an analytics compute resource (Hadoop MapReduce)

Registering Storage Resources

Remote file systems and data curation services like Mytardis mytardis_storage are used as a storage resources.

Remote File System
  1. Navigate to the Chiminey portal.
  2. Log in with your credentials.
  3. Click Settings.
  4. Click Storage Resource from the Settings menu.
  5. Click Register Storage Resource
  6. Click the Remote File System tab.
  7. Enter a unique resource name.
  8. Enter IP address or hostname of the remote file system.
  9. Enter credentials, i.e. username and password. Password is not stored in the Chiminey platform. It is temporarily kept in memory to establish a private/public key authentication from the Chiminey platform to the resource.
  10. Click Register. The newly registered resource will be displayed under Remote File System list.
Registering a remote file system as a storage resource

Figure. Registering a remote file system as a storage resource

MyTardis Storage Resource
  1. Navigate to the Chiminey portal.
  2. Log in with credentials
  3. Click Settings
  4. Click Storage Resource from the Settings menu
  5. Click Register Storage Resource
  6. Click the MyTardis tab.
  7. Enter a unique resource name.
  8. Enter IP address or hostname of the MyTardis instance.
  9. Enter credentials, i.e. username and password. Username and password are stored on the Chiminey platform.
  10. Click Register. The newly registered storage resource will be displayed under MyTardis list.
Registering MyTardis, a data curation service

Figure. Registering MyTardis, a data curation service.

Updating Resources

Follow the steps below to change he details of registered resources.
  1. Navigate to the Chiminey portal.
  2. Log in with credentials
  3. Click Settings
  4. From the Settings menu, depending on which resource you wish to update, click either Compute Resource or Storage Resource. All registered resources will be listed.
  5. Locate the resource you wish to update, then click Update.
  6. Make the changes, and when finished click Update

Removing Resources

In order to remove a registered resource, follow all the steps from Updating Resources but click Remove instead of Update. The resource will be removed from the resources’ list.

Job Management

The end-user submits, monitors, and terminates jobs via the Chiminey portal. Before going into details about job management, we first discuss the Chiminey UI for submitting jobs.

The Job Submission UI

Job Submission UI for wordcount smart connector

Figure. Job Submission UI for wordcount smart connector

The aim of the following discussion is to understand the job submission UI, and therefore be able to run any smart connector job without difficulty. The job submission UI is accessed by clicking Create Job tab. The above figure shows the job submission UI of wordcount smart connector. The Chiminey job submission UI is composed of a list of activated smart connectors, and the submission form of the selected smart connector. The submission form is divided into various sections. In general, each submission form has at least three sections: 1. Presets, 2. Compute Resource and 3. Locations.

1. Presets

The end-user can save the set of parameters values of a job as a preset. Each preset must have a unique name. Using the unique preset name, the end-user can retrieve, update and delete saved presets.

2. Compute Resource

This section includes the parameters that are needed to utilise the compute resource associated with the given smart connector. For instance, hadoop compute resources need only the name of the registered hadoop cluster (see Analytics Compute Resource), while the cloud compute resource needs the resource name as well as the total VMs that can be used for the computation. Note that the names of all registered compute resources are automatically populated to a dropdown menu on the submission form.

3. Locations

These parameters are used to specify either input or output directories on a registered storage resource. Each location consists of two parameters: a storage location and a relative path. Storage location is a drop-down menu that lists the name of all registered storages and, their corresponding root path. A root path is an absolute path to the directory on the storage resource onto which all input and output files will be saved. Relative path is the name of a subdirectory of the root path that contains input and/or output files. In the case of input locations, Chiminey retrieves the input files that are needed to run the smart connector job from this subdirectory. In the case of output location, Chiminey will save the output of the smart connector job to the subdirectory.

4. Optional Parameter Sections

Some job submission forms include one or more of the following sections:

Reliability
Fault tolerance support is provided to each smart connector job. How- ever, the enduser can limit the degree of such support using the reliability parameters: reschedule failed processes and maximum retries.
Sweep
Sweep allows end-users to run multiple jobs simultaneously from a single submission. The sweep allows end-users to provide ranges of input values for parameters, and the resulting set of jobs produced span all possible values within that parameter space. These ranges of parameters are defined at job submission time, rather than being hard-coded in the definition of the smart connector. The common use- cases for this feature are to generate multiple results across one or more variation ranges for later comparison, and to quickly perform experi- mental or ad-hoc variations on existing connectors. Endusers specify the parameter(s) and their possible values via the sweep parameter.
Data curation resource
This section provides the parameters that are needed to curate the output of a smart connector job. The section includes a drop- down menu that is populated with the name registered data curation services like MyTardis.
Domain-specific parameters
These parameters are needed to guide the execution of the domain-specific payload of a given smart connector. wordcount smart connector has Word Pattern while hrmclite has pottype, error threshold, and others.

Job Submission

Follow the steps below

  1. Navigate to the Chiminey portal
  2. Log in with your credentials
  3. Click Create Job from the menu bar
  4. Select the smart connector from the list of smart connectors
  5. Enter the values for the parameters of the selected smart connector.
  6. Click Submit Job button, then OK

Job Monitoring

Once a job is submitted, the end-user can monitor the status of the job by clicking Jobs tab. A job status summary of all jobs will be displayed. The most recently submitted job is displayed at the top. Click Info button next to each job to view a detailed status report.

Monitoring a job

Figure. Monitoring a job

Job Termination

The Jobs page also allows to terminate submitted jobs. To terminate a job, check the box at the end of the status summary of the job, click Terminate selected jobs button at the end of the page. The termination of the selected jobs will be scheduled. Depending on the current activity of each job, terminating one job may take longer than the other.

Terminating a job

Figure. Terminating a job

Presets Management

The end-user can save the set of parameters values of a job as a preset. Each preset must have a unique name. Using the unique preset name, the end-user can retrieve, update and delete saved presets.

Managing presets

Figure. Managing presets

Adding Preset

  1. Fill the parameter values for the job you are about to submit
  2. Click + button next to the Preset Name drop down menu
  3. Enter a unique name for the new preset
  4. Click Add

Retrieving Preset

  1. Select the preset name from the Preset Name drop down menu. The parameters on the submit job will be filled using parameters values that are retrieved from the selected preset.

Updating Preset

  1. Select the preset name from the ‘Preset Name’ drop down menu.
  2. Change the value of parameters as needed
  3. Save your changes by clicking the save button next to the Preset Name drop down menu.

Deleting Preset

  1. Select the preset name from the Preset Name drop down menu.
  2. Click - button next to the ‘Preset Name’ drop down menu. Then, confirmation box appears.
  3. Click OK to confirm.

Developer Manual

Smart Connector: the core concept within Chiminey

A smart connector is the core concept within Chiminey that enables endusers to perform complex computations on distributed computing facilities with minimal effort. It uses the abstractions provided by Chiminey to define transparent automation and error handling of complex computations on the cloud and traditional HPC infrastructure.

Stage

A stage is a unit of computation within Chiminey. Each stage hast at least the following elements:

  • validation:

    Before the execution of a smart connector starts, the Chiminey server checks whether the constraints of all stages of the smart connector are met. This is done by invoking input_valid(self, ...) method of each stage of the smart connector.

  • pre-condition:

    The Chiminey platform uses pre-conditions to determine the stage that should be executed next. The Chiminey platform invokes the method is_triggerred(self, ...) in order to check whether the pre-condition of a particular stage is met.

  • action:

    This is the main functionality of a stage. Such functionality includes creating virtual machines, waiting for computations to complete, and the like. Once the Chiminey platform determines the next stage to execute, the server executes the stage via the process(self, ...) method.

  • post-condition:

    This is where the new state of the smart connector job is written to a persistent storage upon the successful completion of a stage execution. During the execution of a stage, the state of a smart connector job changes. This change is saved via the output(self, ...) method.

The relationship between smart connectors and stages

A smart connector is composed of stages, each stage with a unique functionality. Following are the predefined stages that make up a smart connector (the predefined stages are located at chiminey/corestages):

  • parent:

    Provides a handle to which all stages are within a smart connector are attached when a smart connector is registered within Chiminey. Contains methods that are needed by two or more stages.

  • configure:

    Prepares scratch spaces, creates MyTardis experiments, ...

  • create:

    Creates virtual machines on cloud-based infrastructure.

  • bootstrap:

    Sets up the execution environment for the entire job, e.g. installs dependencies.

  • schedule:

    Sets up the execution environment for individual task, and schedules tasks to available resources. A job is composed of one or more tasks. This stage is especially important when the job has more than one task.

  • execute:

    Starts the execution of each task.

  • wait:

    Checks whether a task is completed or not. Collects the output of completed tasks.

  • transform:

    Prepares the input to the computation in the next iteration. Some smart connector jobs, for example Hybrid Reverse Monte Carlo simulations, have more than one iterations. When all tasks in the current iteration are completed and their corresponding output is collected, the transform stage prepares the input to the upcoming tasks in the next iteration.

  • converge:

    Checks whether convergence is reached, where a job has more than one iteration. A convergence is assumed to be reached when either some criterion or the maximum number of iterations is reached.

  • destroy:

    Terminates previously created virtual machines.

Creating a smart connector

Creating a smart connector involves completing three tasks:

  1. providing the core functionality of the smart connector,
  2. attaching resources and optional non-functional properties, and
  3. registering the new smart connector with the Chiminey platform.

Each of the three tasks is discussed below by creating an example smart connector. This smart connector generates a random number with a timestamp, and then writes the output to a file.

NB: Login to the Chiminey docker container.

  • For Mac OS X and Windows users, open Docker Quickstart Terminal. For linux-based OS users, login to your machine and open a terminal.

  • Login to the chiminey docker container:

    $ cd docker-chiminey
    $ ./chimineyterm
    
The Core Function

The core functionality of a smart connector is provided either via a payload or by overriding the run_task method of chiminey.corestages.execute.Execute class. In this example, we use a minimal payload to provide the core functionality of this smart connector. Thus, we will prepare the following payload.

payload_randnum/
|--- process_payload
│    |--- main.sh

Below is the content of main.sh:

#!/bin/sh
OUTPUT_DIR=$1
echo $RANDOM > $OUTPUT_DIR/signed_randnum date > $OUTPUT_DIR/signed_randnum
# --- EOF ---

Notice OUTPUT_DIR. This is the path to the output directory, and thus Chiminey expects all outputs to be redirected to that location. The contents of OUTPUT_DIR will be transferred to the output location at the end of each computation.

Attaching resources and non-functional properties

Resources and non-functional properties are attached to a smart connector by overriding get_ui_schema_namespace method of chiminey.initialisation.coreinitial.CoreInitial class. New domain-specific variables can be introduced via get_domain_specific_schemas method. In this example, we will need to attached a unix compute resource for the computation, and a storage resource for the output location. However, we will not add a non-functional property.

Under chiminey/, we create a python package randnum, and add initialise.py with the following content

from chiminey.initialisation import CoreInitial
from django.conf import settings
class RandNumInitial(CoreInitial):
def get_ui_schema_namespace(self):
        schemas = [
                settings.INPUT_FIELDS[’unix’],
                settings.INPUT_FIELDS[’output_location’],
] return schemas
# ---EOF ---

NB: The list of available resources and non-functional properties is given by INPUT_FIELDS parameter in chiminey/settings_changeme.py

Registration

The final step is registering the smart connector with the Chiminey platform. The details of this smart connector will be added to the dictionary SMART CONNECTORS in chiminey/settings changeme.py. The details include a unique name (with no spaces), a python path to RandNumInitial class, the description of the smart connector, and the absolute path to the payload.

"randnum": {
           "name": "randnum",
           "init": "chiminey.randnum.initialise.RandNumInitial",
           "description": "Randnum generator, with timestamp",
           "payload": "/opt/chiminey/current/payload_randnum"
},

Finally, restart the Chiminey platform and then activate randnum smart connector. You need to exit the docker container in order to restart:

$ exit
$ sh restart
$ ./activatesc randnum
Food for Thought

In the example above, we created a smart connector that generates a random number on a unix-based machines. Even though the random number generator a simple smart connector, the tasks that are involved in creating a smart connector for complex programs is similar. If your program can be executed on a cloud, HPC cluster, hadoop cluster, then this program can be packaged as a smart connector. The huge benefit of using the Chiminey platform to run your program is you don’t need to worry about how to manage the execution of your program on any of the provided compute resources. You can run your program on different types of compute resources with minimal effort. For instance, to generate random on a cloud-based virtual machine, we need to change only one word in get_ui_schema_namespace method. Replace unix by cloud. Then, restart Chiminey, and activate your cloud-based random number generator.

Check the various examples are given in this documentation. These examples discuss the different types of compute and storage resources, and non-functional properties like reliability and parameter sweep.

Parameter Sweep

The Chiminey platform provides two types of parameter sweeps:

External Parameter Sweep

External parameter sweep allows end-users to simultaneously submit and run multiple jobs. The external sweep gives power to the end-users to provide a range of input values for a set of parameters of their choice, and the resulting set of jobs span all possible values from that parameter space.

The set of parameters are defined as part of input data preparation, rather than being “hard-coded” to the definition of the smart connector. This is done using templating language. Here are the steps:

  1. Identify the input files that contain the parameters of your choice.
  2. Surround each parameter name with double curly brackets. Suppose an input file entry is var1 15. Replace this line by {{var1}} 15; where 15 is the default value.
  3. Save each input file as filename_template.

The end-user provides the range of values of these parameters via a sweep map during job submission.

The common usecases for the external parameter sweep are to generate multiple results across one or more variation ranges for later comparison, and to quickly perform experimental or ad-hoc variations on existing smart connectors.

Internal Parameter Sweep

Internal parameter sweep allows developers to create a smart connector that spawns multiple independent tasks during the smart connector’s job execution. When a smart connector is created, the developer includes a set of parameters that will determine the number of tasks spawned during the execution of the smart connector.

The developer uses a sweep map to specify a range of values for the selected set of parameters during a smart connector definition. This is done by subclassing Parent, which is located at chiminey/corestages/parent.py, and overwriting the method get_internal_sweep_map(self, ...) to include the new sweep map. The default sweep map generates one task.

def get_internal_sweep_map(self, settings, **kwargs):
    rand_index = 42
    map = {'val': [1]}
    return map, rand_index

NB: A smart connector job that is composed of multiple tasks, due to an internal parameter sweep, is considered to be complete when each task either finishes successfully or fails beyond recovery.

Sweep Map

A sweep map is a JSON dictionary that is used to specify a range of values for a set of parameters.
  • The key of the dictionary corresponds to a parameter name.
  • The value of the dictionary is a list of possible values for that parameter.

Below is an example of a sweep map.

sweep_map = {"var1": [7,9], "var2": [42]}

The cross-product of the values of the parameters in a sweep map is used to determine the minimum [*] number of tasks or jobs generated during job submission. The above sweep map, for example, generates

  • two jobs if used for external parameter sweep, or
  • two tasks per job if used for internal parameter sweep
Imapct of unknown parameters in a sweep map

An unknown parameter is a parameter that is not needed during the execution of a smart connector. A known parameter, on the other hand, is a parameter whose value is needed for the correct functioning of a smart connector.

Including an unknown parameter in a sweep map does not have any ill-effect during execution. However, this parameter causes an increase in the number of generated tasks/jobs, provided that the number of the values of the unknown parameter is more than one.

Suppose var1 and var2 are known parameters, and x is an unknown parameter of a specific smart connector; and the sweep map is {"var1": [7,9], "var2": [42], "x": [1,2]}.

  • If the sweep map is used for external parameter sweep, the number of jobs doubles due to the inclusion of parameter x with two values. If the sweep map is used for internal sweep, the number of tasks doubles as well. If the value of x is changed to [1,2,3], the number of jobs/tasks triples, and so on.

The additional jobs or tasks waste computing, storage and network resources. However, there are cases where such feature is useful.

  • The end-user can use this feature to run jobs with identical inputs, and then compare whether the jobs produce the same output.
  • If each task has unpredictable output irrespective of other variables being constant, the developer can use the feature to run many of these tasks per job, each task with different output. For example, generating a random number without fixing the seed almost always guarantees a new number.
[*]The total number of tasks that are generated per job depends on the type of the smart connector. In addition to the sweep map, domain-specific variables or constraints play a role in determining the number of tasks per job.

Payload

A payload is a set of system and optionally domain-specific files that are needed for the correct execution of a smart connector. The system files are composed of bash scripts while the domain-specific files are developer provided executables. The system files enable the Chiminey platform to setup the execution environment, execute domain-specific programs, and monitor the progress of setup and execution.

NB: All smart connectors that are executed on a cloud and a cluster infrastructure must have a payload. However, smart connectors that are executed on unix servers do not need a payload unless the execution is asynchronous.

Below is the structure of a payload.

payload_name/
|--- bootstrap.sh
|--- process_payload
│    |--- main.sh
│    |--- schedule.sh
│    |--- domain-specific executable

The names of the files and the directories under payload_name, except the domain specific ones, cannot be changed.

  • bootstrap.sh includes instructions to install packages, which are needed by the smart connector job, on the compute resource.
  • schedule.sh is needed to add process-specific configurations. Some smart connectors spawn multiple processes to complete a single job. If each process needs to be configured differently, the instruction on how to configure each process should be recorded in schedule.sh.
  • main.sh runs the core functionality of the smart connector, and writes the output to a file. Chiminey sends the path to input and output directories via command-line arguments:

the first argument for input and the second for output. The smart connector developer can read inputs from the input directory, and redirect outputs of the job to the output directory. Upon the completion of the smart connector job, Chiminey will transfer the content of the output directory to the end-user’s designated location.

  • domain-specific executables are additional files that may be needed by main.sh.

Not all smart connector jobs require new packages to be installed, process-level configuration or additional domain-specific executables. On such cases, the minimal payload, as shown below, can be used.

payload_name/
|--- process_payload
│    |--- main.sh

NB: Sample payloads are available under each example smart connector, at the Chiminey Github Repository.

Chiminey User Interface

The Chiminey platform automatically generates a job submission web page for each smart connector. However, this web page contains only a drop down menu of presets. The web page will also contain a parameter sweep input field for smart connectors with a sweep feature. Since these two input fields are not sufficient to submit a job, the developer should specify the input fields that are needed to submit a particular smart connector job. This is done during the definition of the smart connector.

Within the Chiminey platform, there are various input field types, organised in groups like compute resource variables, location variables and domain-specific variables. The input fields, except the domain-specific ones, are provided via INPUT_FIELDS parameter in chiminey/settings_changeme.py. The following table shows the list of input field types and their description.

Input Field Type Description
unix
Dropdown menu containing the registered
HPC compute resources.
cloud
Dropdown menu of registered cloud resources,
number of VMs to be used for the job.
hadoop
Dropdown menu of registered hadoop clusters.
output_location
Dropdown menu of registered storage resources
(i.e. remote file system) with root path,
and a text field for specifying directories
under the root path.
input_location
Same as output location.
location
Input and output location.
reliability
Set of fields to control the degree of the
provided fault tolerance support.
mytardis
Set of fields to enable end users to curate
the input and output of their smart connector
job on MyTardis.
hrmclite
Domain-specific input fields needed
to run HRMCLite jobs.
hrmc
Domain-specific input fields needed
to run HRMC jobs.
wordcount
Domain-specific input fields needed to run
wordcount jobs.

Constructing Smart Connector Input Fields

Here, we see how to include the input fields that are needed for submitting a smart connector job. When a smart connector is created, one of the tasks is attaching resources and non-functional properties via input field types. This task is done by overriding get_ui_schema_namespace(self) of the CoreInitial class. The CoreInitial class is available at chiminey/initialisation/coreinitial.

Suppose the new smart connector is cloud-based and writes its output to a unix server. Therefore, the job submission page of this smart connector must include two input field types that enables end-users to provide a) a cloud-based compute resource and b) an output location. Suppose CloudSCInitial extends the CoreInitial class:

from chiminey.initialisation import CoreInitial
from django.conf import settings
class CloudSCInitial(CoreInitial):
def get_ui_schema_namespace(self):
    schemas = [
            settings.INPUT_FIELDS['cloud'],
            settings.INPUT_FIELDS['output_location'],
] return schemas

# ---EOF ---
Including domain-specific input fields

Input field types that are included within the Chiminey platform are generic and are included within the platform. However domain-specific input fields must be defined when needed. A domain-specific input field type is provided by overriding get_domain_specific_schemas(self) of the CoreInitial class. This method will return a list of two elements:

  1. The description of the input field type e.g. HRMCLite Smart Connector

  2. A dictionary whose keys are the names of domain-specific input fields, their values are dictionaries with the following keys:

    • type: There are three types of input fields: numeric (models.ParameterName.NUMERIC), string (models.ParameterName.STRING), list of strings (models.ParameterName.STRLIST). numeric and string inputs have a text field while a list of strings has a drop-down menu. Enduser inputs are validated against the type of the input field.
    • subtype: Subtypes are used for additional validations: numeric fields can be validated for containing whole and natural numbers.
    • description: The label of the input field.
    • choices: If the type is list of strings, the values of the dropdown menu is provided via choices.
    • ranking: Ranking sets the ordering of input fields when the fields are displayed.
    • initial: The default value of the field.
    • help_text: The text displayed when a mouse hovers over the question mark next to the field.

Below are two examples of domain-specific input field types: wordcount and HRMCLite smart connector.

  • WordCount smart connector input field type
def get_domain_specific_schemas(self):
        schema_data =  [u'Word Count Smart Connector',
             {
                 u'word_pattern': {'type': models.ParameterName.STRING,
                                  'subtype': 'string',
                                  'description': 'Word Pattern',
                                  'ranking': 0,
                                  'initial': "'[a-z.]+'",
                                  'help_text': 'Regular expression of filtered words'},
             }
            ]
        return schema_data
  • HRMCLite smart connector input field type
def get_domain_specific_schemas(self):
    schema_data =  [u'HRMCLite Smart Connector',
         {
             u'iseed': {'type': models.ParameterName.NUMERIC,
                        'subtype': 'natural',
                        'description': 'Random Number Seed',
                        'ranking': 0,
                        'initial': 42,
                        'help_text': 'Initial seed for random numbers'},
             u'pottype': {'type': models.ParameterName.NUMERIC,
                          'subtype': 'natural',
                          'description': 'Pottype',
                          'ranking': 10,
                          'help_text': '',
                          'initial': 1},
             u'error_threshold': {'type': models.ParameterName.STRING,
                                  'subtype': 'float',
                                  'description': 'Error Threshold',
                                  'ranking': 23,
                                  'initial': '0.03',
                                  'help_text': 'Delta for iteration convergence'},
             u'optimisation_scheme': {'type': models.ParameterName.STRLIST,
                                      'subtype': 'choicefield',
                                      'description': 'No. varying parameters',
                                      'ranking': 45,
                                      'choices': '[("MC","Monte Carlo"), ("MCSA", "Monte Carlo with Simulated Annealing")]',
                                      'initial': 'MC', 'help_text': '',
                                      'hidefield': 'http://rmit.edu.au/schemas/input/hrmc/fanout_per_kept_result',
                                      'hidecondition': '== "MCSA"'},
             u'fanout_per_kept_result': {'type': models.ParameterName.NUMERIC,
                                        'subtype': 'natural',
                                         'description': 'No. fanout kept per result',
                                         'initial': 1,
                                         'ranking': 52,
                                         'help_text': ''},
             u'threshold': {'type': models.ParameterName.STRING,
                            'subtype': 'string',
                            'description': 'No. results kept per iteration',
                            'ranking': 60,
                            'initial': '[1]',
                            'help_text': 'Number of outputs to keep between iterations. eg. [2] would keep the top 2 results.'},
             u'max_iteration': {'type': models.ParameterName.NUMERIC,
                                'subtype': 'whole',
                                'description': 'Maximum no. iterations',
                                'ranking': 72,
                                'initial': 10,
                                'help_text': 'Computation ends when either convergence or maximum iteration reached'},
         }
        ]

    return schema_data

Examples

Here, we use the following examples to show the different features of a smart connector and how a smart connector is defined and registered within a Chiminey server.

Quick Example: Random Number Smart Connector

In this example, we create a basic smart connector that generates two random numbers on a unix machine, saves the numbers to a file, and then transfers the file to a provided output location. The unix machine must have ssh service enabled.

This smart connector has already been discussed in section Creating a smart connector.

Word Count Smart Connector

HRMCLite Smart Connector

The Hybrid Reverse Monte Carlo (HRMC) Smart Connector

Note

This example is significantly more complicated than the previous examples. Therefore we describe here the unique features of this connector and invite the reader to read the source code for this connector in detail. It combines a number of features from the previous examples and uses the same overall architecture.

The Hybrid Reverse Monte Carlo Smart Connector, hereafter HRMC SC, is designed to run the implementation of an HRMC simulation by George Opletal. The HRMC SC runs HRMC simulations on a cloud compute resource. It reads inputs from a remote file system, and then writes output to a remote file system and a data curation service, i.e. MyTardis. The HRMC SC enables end-users to control the degree of the provided fault tolerance support. Furthermore, this smart connector includes a sweep functionality to enable end-users to simultaneously execute multiple HRMC jobs from a single submission.

The HRMC SC and related topics will be discussed as follows:

Hybrid Reverse Monte Carlo - Source Code Version 2.0 (Oct 2012)
Code development by:
Dr. George Opletal
Applied Physics RMIT, Melbourne Australia.
Contributions to code development:
Dr. Brendan O’Malley
Dr. Tim Petersen

Published in:

  1. Opletal, T. C. Petersen, I. K. Snook, S. P. Russo, HRMC_2.0: Hybrid Reverse Monte Carlo method with silicon, carbon and germanium potentials, Com. Phys. Comm., 184(8), 1946-1957 (2013).

License: CPC License: http://cpc.cs.qub.ac.uk/licence/licence.html

HRMC Core Function

The core functionality of the HRMC SC is provided through a payload. The HRMC payload is similar to the following.

payload_hrmc/
|--- bootstrap.sh
|--- process_payload
│    |--- HRMC2.tar.gz
|    |--- PSDCOde.tar.gz
│    |--- schedule.sh
│    |--- main.sh

The HRMC SC requires packages like dos2unix, fortran compiler. Thus, all the required dependancies are specified in bootstrap.sh. The content of bootstrap.sh is as follows:

#!/bin/bash

 yum -y install dos2unix gcc-gfortran compat-libgfortran-41 gcc-gfortran.x86_64

The payload includes domain-specific executables, i.e. HRMC2.tar.gz and PSDCOde.tar.gz. The schedule.sh of HRMC SC contains process-specific configurations. schedule.sh is responsible to extract the executables for each HRMC process. Below shows the content of schedule.sh.

#!/bin/bash
# version 2.0

INPUT_DIR=$1
OUTPUT_DIR=$2

tar --extract --gunzip --verbose --file=HRMC2.tar.gz
f95 HRMC2/hrmc.f90 -fno-align-commons -o HRMC

tar --extract --gunzip --verbose --file=PSDCode.tar.gz
gfortran PSDCode/PSD.f -o PSDCode/PSD

main.sh is the core of HRMC SC. Recall that Chiminey sends the path to input (``INPUT_DIR`) and output (OUTPUT_DIR) directories via command-line arguments<payload>`. Here, the SC developer moves the HRMC executable, which was extracted by schedule.sh, to the input directory. The SC developer changes its working directory to INPUT_DIR, run HRMC, and redirect the execution output to OUTPUT_DIR. When HRMC is completed, the SC developer moves additional files to OUTPUT_DIR. As the next major step, the SC developer runs the PSD executable, which was extracted by schedule.sh. Once the execution is completed, the necessary files are moved to OUTPUT_DIR.

NB: Running HRMC and PSD takes a long time. However, the SC developer should not be concerned about this as Chiminey will ensure that all tasks are run asynchronously.

#!/bin/bash
# version 2.0

INPUT_DIR=$1
OUTPUT_DIR=$2

cp HRMC $INPUT_DIR/HRMC
cd $INPUT_DIR
./HRMC >& ../$OUTPUT_DIR/hrmc_output
cp input_bo.dat ../$OUTPUT_DIR/input_bo.dat
cp input_gr.dat ../$OUTPUT_DIR/input_gr.dat
cp input_sq.dat ../$OUTPUT_DIR/input_sq.dat
cp xyz_final.xyz  ../$OUTPUT_DIR/xyz_final.xyz
cp HRMC.inp_template ../$OUTPUT_DIR/HRMC.inp_template
cp  data_errors.dat   ../$OUTPUT_DIR/data_errors.dat

cp -f xyz_final.xyz ../PSDCode/xyz_final.xyz
cd ../PSDCode; ./PSD >&  ../$OUTPUT_DIR/psd_output
cp PSD_exp.dat ../$OUTPUT_DIR/
cp psd.dat ../$OUTPUT_DIR/
Attaching Resources and Non-functional properties
Registering the HRMC SC
Setup

As with the previous examples, we setup the new connector payload:

mkdir -p /var/chiminey/remotesys/my_payloads
cp -r  /opt/chiminey/current/chiminey/examples/hrmc2/payload_hrmc /var/chiminey/remotesys/my_payloads/

Then register the new connector within chiminey:

sudo su bdphpc
cd /opt/chiminey/current
bin/django hrmc
Yes

This example is significantly more complicated than the previous random number examples. Therefore we describe here the unique features of this connector and invite the reader to read the source code for this connector in detail. It combines a number of features from the previous examples and uses the same overall architecture.

The Input Directory

As described earlier, each connector in Chiminey system can elect to specify a payload directory that is loaded to each VM for cloud execution. This payload is fixed for each type of connector.

However, if practice you would likely want to vary the behaviour of different runs of the same connector, to change the way a process is executed or perform exploratory analysis.

This is accomplished in Chiminey by the use of a special input directory. This is one of the most powerful features of a smart connector as it allows individual runs to be fully parameterised on the initial input environment and environment during execution.

Ideally the payload directory would contains source or code for the application, and the input directory would contain configuration or input files to that application.

The input directory is a remote filesystem location (like the output directory) defined and populated before execution, which contains files that will be loaded into the remote copy of the payload after it has been transferred to the cloud node, for every run. Furthermore the contents of input files in that directory can be varied at run time.

Any files within the input directory can be made into a template by adding the suffix _template to the filename. Then, this file is interpreted by the system as a Django template file.

Consider the application ``foo` has its source code in a payload, but requires a ``foo.inp``file containing configuraiton information. For example:

# foo input file
iseed 10
range1 45
range2 54
fudgefactor 12

is an example input for one run. To parameterise this file you rename it to foo.inp_template and replace the values that need to vary with equivalent template tags:

# foo input file
iseed {{iseed}}
range1 {{range1}}
range2 {{range2}}
fudgefactor 12

The actual values to be used are substituted at runtime by the system. THe values can come from the external sweep map, the internal sweep map, domain-specific values in the submission page, and constant values set within the input directory.

For example, the iseed value may be an input field on the submission page, the range1 value may be predefined to be constant during all runs, and the range2 has to go between the values 50--52.

This parameterisation is performed using a values file, which is a special file at the top of the input directory. This JSON dictionary contains values to be instantiated into template files at run time. The values files included in the original input directory can contain constant values that would then apply generally to any connector using that input directory.

For this example, we the directory would include a file values containing:

{
    "range1": 45
}

Then initially, all runs of foo will include:

range1 45

in the foo.inp file

However, Chiminey also automatically populates the values directory with other key/value s representing the data typed into the job submission page form fields, the specific values from the sweep map for that run. All these values can be used in instantiation of the template files.

For this example, if at jobs submission time the user entered iseed as 10, and the sweep map values as {"range2": [50, 51]} then external sweep will produce multiple processes each with a values file across the range range2. For example:

{
    "iseed": 10
    "range1": 45,
    "range2": 50,

}

or:

{
    "iseed": 10
    "range1": 45,
    "range2": 51,
}

The foo.inp_template file is matched against the appropriate values file, to create the required input file. For example:

# foo input file
iseed 10
range1 45
range2 50
fudgefactor 12

or:

# foo input file
iseed 10
range1 45
range2 51
fudgefactor 12

Hence these are are the foo.inp files for each run.

The use case for such a connector:

  1. Prepare a payload containing all source code and instructions to compile as before.

  2. Prepare a remote input directory containing all the input files needed by the computation. If the contents of any of these files need to vary, then rename the files and add {{name}} directives to identify the points of variation. Names are:

    1. keys from the input schemas within the submission page.
    2. constant values for the whole computation.
  3. Optionally add a ./values file containing a JSON dictionary of mappings between variables and values. These entries are constant values for the whole computation.

  4. During execution, Chiminey will load up values files and propagate them in input and output directories, will put values corresponding to all input values, individual values from the space of sweep variables. These variables will be substituted into the template to make an original input file suitable for the actual execution.

In the HRMC connector, the HRMC.inp file is templated to allows substitution of values from both the job submission page and from the sweep variable. See input_hrmc/initial directory and the inluded HRMC.inp_template and values files.

Complex Internal Sweeps

The randnuminternalsweep connector defined a simple map in the parent stage that maps an input into two variations based on a variable var. While that value was not used in that example, we can see that if a input directory was used then each of the two variations would get different values for the var variable in the values file and could be used in any input template file.

For the HRMC smart connector, the mapping is significantly more complicated. In the get_internal_sweep_map method of hrmcparent.py, the map is definedin stages using existing variables (in the values file), the values in the original form, plus new variables based on random numbers and on the current iteration of the calculation. Thus the number of processes and their starting variables can be specialised and context sensitive and then instantiated into template files for execution.

Use of Iterations

In the random numbers the standard behaviour was to execute stages sequentially from Configure through to Teardown. However, in the HRMC example, we support an run_setting variable system/id which allows a set of stages to be repeated multiple times and two new core stages, Transform and Converge. These stages are specialised in the HRMC example:

  • After the results are generated during the execution phase, the HRMCTransform stages calculates a criterion value (the compute_psd_criterion method). The execution results are then prepared to become input for a next iteration (the process_outputs method)
  • In the HRMCConverge stage, the new criterion value is then compared a previous iterations’ value and if the difference is less than a threshold, then the smart connector execution is stopped. Otherwise, the value system/id is incremented and the triggering state for the execution phase is created which causes these stages to be re-executed. Finally, to handle the situation where the criterion will diverges or is converging too slowly, the HRMCConverge stage also halts the computation is the system/id variable exceeds a fixed number of iterations.

See the hrmctransform.py and hrmcconverge.py modules for more details.

Complex Mytardis Interactions

The HRMC example, expands on the MyTardis experiment created in the randonnumber example.

As before the HRMCConverage defines a curate_data method, and the HRMCTransform and HRMCConverge define a curate_dataset method. However, the later methods are significantly more complicated than the previous example.

The mytardis/create_datadata method takes a function for the dataset_name as before, which has a more complicated implementation. However, this example also uses the dfile_extract_func argument which is a dict from datafile names to functions. For all contained datafiles within the dataset, their names are matched to this dictionary, and when found, the associated function is executed with a file pointer to that files contents. The function then results the graph metadata required.

For example, HRMCTransform includes as an argument for mytardis.create_dataset:

dfile_extract_func= {'psd.dat': extract_psd_func,
'PSD_exp.dat': extract_psdexp_func,
'data_grfinal.dat': extract_grfinal_func,
'input_gr.dat': extract_inputgr_func}

Here for any datafile in the new dataset named psd.dat chiminey will run:

def extract_psd_func(fp):
    res = []
    xs = []
    ys = []
    for i, line in enumerate(fp):
        columns = line.split()
        xs.append(float(columns[0]))
        ys.append(float(columns[1]))
    res = {"hrmcdfile/r1": xs, "hrmcdfile/g1": ys}
    return res

Here the function returns a directionry containing mappings to two lists of floats extracted from the datafile psd.dat. This value is then added as a metadata field attached to that datafile. For example:

graph_info   {}
name         hrmcdfile
value_dict   {"hrmcdfile/r1": [10000.0, 20000.0, 30000.0, 40000.0, 50000.0, 60000.0, 70000.0, 80000.0, 90000.0, 100000.0, 10000.0, 20000.0], "hrmcdfile/g1": [21.399999999999999, 24.27, 27.27, 25.649999999999999, 22.91, 20.48, 18.649999999999999, 17.16, 16.34, 16.219999999999999, 15.91, 15.460000000000001]}
value_keys   []

This can then be data to be used by the dataset level graph hrmcdset described in the dataset_paramset argument of the create_dataset method.

API Reference

Chiminey Stage APIs

mytardis – MyTardis APIS

The MyTardis module provides functions that allow publishing Chiminey results to a connected MyTardis System, allowing the online storing, access and sharing capabilities of data and metadata.

Datastructures

paramset

Module Functions and Constants

Example:

def _get_exp_name_for_make(settings, url, path):
                   return str(os.sep.join(path.split(os.sep)[-2:-1]))

               def _get_dataset_name_for_make(settings, url, path):
                   return str(os.sep.join(path.split(os.sep)[-1:]))

               self.experiment_id = mytardis.create_dataset(
                   settings=mytardis_settings,
                   source_url=encoded_d_url,
                   exp_id=self.experiment_id,
                   exp_name=_get_exp_name_for_make,
                   dataset_name=_get_dataset_name_for_make,
                   experiment_paramset=[],
                   dataset_paramset=[
                       mytardis.create_paramset("remotemake/output", [])]
                   )

storage – Storage APIS

This package provides a file-like api for manipulating local and remote files and functions at locations specified by platform instances.

Datastructures
Module Functions and Constants

sshconnection – Manipulation of Remote Resources

Datastructures

ssh_client

Module Functions and Constants

compute – Execution Of Remote Commands

Using an open ssh_client connector from sshconnector, these commands execute commands remotely on the target server.

Datastructures
Module Functions and Constants

messages – Logging communication for Chiminey

This package, modelled off the django logging module, posts status messages for the BDP system. There are two classes of context for the user of this API:

  1. Within stage implementation, messages will be displayed within the status field in the job list UI.
  2. During job submission, messages will be displayed on the redirected page as a header banner.

Messages are processed by a separate high-priority queue in the celery configuration. Note that message delivery may be delayed due to celery priority or db exclusion on the appropriate context, so this function should not be used for real-time or urgent messages.

Datastructures

By convention, error messages are final messages in job execution to indicate fatal error (though job might be restarted via admin tool) and success is used to describe final successful execution of the job.

Module Functions and Constants

Send a msg at the required priority level, as per the django logging module.

Uses contextid field of settings to determine which running context to assign messages.

run_settings – Contextual Namespace for Chiminey

The current state of any BDP calculation is represented as a context model instance, with an associated run_settings instance. This run_setting serves as input, output and scratch symbol table for all job execution.

The contextual namespace is used for numerous purposes in the BDP, including:

  • Input parameters for Directive submission UI dialog
  • Single source of truth for building settings dicts for BDP API modules.
  • Job execution state
  • Diagnostics and visualisation of job progress
  • Stage triggering and scheduling during directive execution

Conceptually run_settings is a set of parameter sets each of which is conformant to a predefined schemas, that are defined in the admin tool.

run_settings is a two-level dictionary, internally serialised to models as needed.

Datastructures

context

A two level dictionary made up of schema keys and values. Conceptually, this structure is equivalent to a two-level python dictionary, but should be accessed via the API below. For example,

{ http://acme.edu.au/schemas/stages : { “key”: id, “id”: 3} }

Keys are concatenation of schema namespace and name, for example: http://acme.edu.au/schemas/stages/key

Module Functions and Constants
chiminey.runsettings.getval(context, key)

Retrieves the current value of the key within the run setttings context.

Parameters:
  • context – current context
  • key – the key to search
Raises:

SettingNotFoundException if the schema part of the key is not in the context

Returns:

the value for the key

chiminey.runsettings.setval(context, key, value)

Sets the value of the key within the run settings context.

Parameters:
  • context – current context
  • key – the key to search
Throws:

runsettings.SettingNotFoundException if the schema part of key is not in the context.

Throws:

runsettings.IncompatibleTypeException if the value is not compatible with the type of the key, according to the associated schema definition.

cloudconnection – Cloud Connection

Datastructures
Module Functions and Constants

corestages – Processing Steps in a directive

This is an abstract class that forms the interface for all directives, both smart connectors and utilties to provides steps in a calcuation.

Datastructures
Module Functions and Constants

simpleui – UI view members